Specifications of the exernal motion sensors for the MOUSE-E-MOTION Universal Data Logger:
General
Cable length |
1 m |
Connector |
MD6 female |
Sensor Type |
Passive ultra-compact infrared sensor (NAiS MP motion sensor ‘NaPiOn’) |
Operating temperature Range |
-25°C to 75°C |
Measuring Range |
0 to 9999 motion detections per record interval |
Max. Resolution |
1 motion detection per second |
|
More information and detailed specifications on the NAiS website |
Spot type



Detection distance |
max. 5 m |
Detection range |
Depending on distance:
The covered range results from lines drawn from the detection zone of the motion sensor with an angle of at least 19° in the longitudinal direction and 11° in the cross direction. The covered base area has a rectangular shape: |
Front View |
Side View |
Base Area |
Motion sensor(Infrared sensor) |
|
 |
 |
 |
Slight Motion type



Detection distance |
max. 5 m |
Detection range |
Depending on distance:
The covered range results from lines drawn from the detection zone of the motion sensor with an angle of at least 46°. The covered base area has a circular shape: |
Side View |
Base Area |
Motion sensor(Infrared sensor) |
|
 |
 |
Standard type
Detection distance |
max. 5 m |
Detection range |
Depending on distance:
The covered range results from lines drawn from the detection zone of the motion sensor with an angle of at least 41° in the longitudinal direction and 50° in the cross direction. The covered base area covered has a rectangular shape: |
Front View |
Side View |
Motion sensor (Infrared sensor) |
Motion sensor (Infrared sensor) |
 |
 |
|
Base Area: |
|
 |
10M type
Detection distance |
max. 10 m |
Detection range |
Depending on distance:
The covered range results from lines drawn from the detection zone of the motion sensor with an angle of at least 46.5° in the longitudinal direction. The covered base area has a rectangular shape. |
|
(Further information is available upon request.) |
If you want more information about the external motion sensors for the MOUSE-E-MOTION Universal Data Logger please contact us at: to the contact form